Memosens CLL47E Four-electrode conductivity sensor Wide
Nº de commande.: CLL47E8APL30
884,44 € Pour 1 pièce(s) plus TVA (21%) plus frais d'expédition
- Fabricant: Endress+Hauser
- Nº d'article: CLL47E-8APL30
- Catégorie: Électrodes
Afficher tous (toutes) Électrodes de Endress+Hauser - Nº catégorie: 90700507
- Mots-clé: conductivity sensors, Oxygen probes
- Validité: 31.12.2026
- Dernière mise à jour: 31.12.2025
- Articles semblables: Montrer (3)
L'image peut différer et contenir des accessoires qui ne sont pas inclus dans la livraison de cet article.
The Memosens 2.0 conductivity sensor CLL47E is a four-electrode conductivity sensor with stainless steel, ceramic and platin is designed for laboratory and sample measurement in the field with wide measuring range.
Thanks to Memosens technology, the sensors provide reliable, highly accurate measurements with a fast response time.
The inductive Memosens coupling between the corresponding Memosens sensor and the mobile CML18 handheld device is insensitive to moisture and corrosion.
The Memosens technology is based on a true plug-and-play principle. Just connect the sensor and you are ready to start your measurements. Measured values, calibration data and history are stored directly in the sensor. This means status values can be read out and a sensor check is also possible. An excellent feature to boost your GLP.
All sensors are supplied pre-calibrated. Thus, they are directly ready for use for your random sample measurement when the corresponding sensor is connected to the associated mobile handheld device Liquiline Mobile CML18.
Thanks to Memosens technology, the sensors provide reliable, highly accurate measurements with a fast response time.
The inductive Memosens coupling between the corresponding Memosens sensor and the mobile CML18 handheld device is insensitive to moisture and corrosion.
The Memosens technology is based on a true plug-and-play principle. Just connect the sensor and you are ready to start your measurements. Measured values, calibration data and history are stored directly in the sensor. This means status values can be read out and a sensor check is also possible. An excellent feature to boost your GLP.
All sensors are supplied pre-calibrated. Thus, they are directly ready for use for your random sample measurement when the corresponding sensor is connected to the associated mobile handheld device Liquiline Mobile CML18.
| Désignation | valeur |
|---|---|
| Désignation type de produit: | Leitfähigkeit |
| Marque déposée: | CLL47E® |
| Diamètre: | 12 mm |
| Longueur: | 120 mm |
| Type de thermocouple: | PT 1000 |
| Paramètre: | Conductivité |
| Sonde de température intégrée: | Oui |
| Temperaturesensor type: | PT-1000 |
| Sensor signal : | Numérique |
| Automatic sensor identification: | Oui |
| Branchement: | Tête enfichable |
| Désignation | valeur |
|---|---|
| WEEE obligation: | Oui |
| WEEE registration number: | DE65437134 |
| WEEE brand according to EAR register: | Endress+Hauser (Deutschland) GmbH+ Co.KG |
| WEEE type of equipment: | Small equipment for use in other than private households only |